Description
- Graphic backlit display with date and time, stability indicator and alarms
- Dual channel meter for pH and conductivity measurements
- One to six point pH calibration with 0.001 pH resolution
- Automatic buffer recognition with four pH buffer sets or custom buffer option
- pH slope and offset display
- Conductivity, TDS (total dissolved solids), salinity and resistivity modes
- Automatic or manual temperature compensation, displayed in °C or °F
- Password protection of calibration and setup modes
- 500 data set storage
- RS232 and USB interfaces
- Multilanguage interface with English, German, Chinese, French, Italian and Spanish
- Optional stirring probe (Cat. No. 13-620-BSP) with five speed settings
NIST-Traceable Calibration Model (-CERT)
- Help meet ISO, FDA, USDA and EPA quality assurance guidelines
- Includes meter accuracy at five test points across pH range
- Includes meter accuracy at five test points across corresponding mV range
- Testing performed by accredited laboratory, includes NIST-Traceable certificate
Specifications
pH Range: -2.000 to 20.000 pH
pH Resolution: 0.1, 0.01, 0.001 pH
pH Accuracy: ±0.002 pH
mV Range: ±2000.0mV
mV Resolution: 0.1mV
mV Accuracy: ±0.2mV or ±0.05 %, whichever is greater
mV Offset Adjustment: Up to ±150mV
Conductivity Range: 0.00μS to 500.0mS
Conductivity Resolution: 0.01, 0.1μS; 0.001, 0.01, 0.1mS
Conductivity Accuracy: ±1 % full scale
TDS Range: 0.00ppm to 500 ppt (TDS factor 1.00)
TDS Resolution: 0.01, 0.1 ppm; 0.001, 0.01, 0.1 ppt
TDS Accuracy: ±1 % full scale
Salinity Range: 0 to 80.0 ppt
Salinity Resolution: 0.01, 0.1 ppm; 0.001, 0.01, 0.1 ppt
Salinity Accuracy: ±1 % full scale
Resistivity Range: 2.000 Ohm to 20.0 MOhm
Resistivity Resolution: 0.01, 0.1 Ohm; 0.001, 0.1 kOhm; 0.01 MOhm
Resistivity Accuracy: ±1 % full scale
Temperature Range: 0° to 100°C (32° to 212.0°F)
Temperature Resolution: 0.1°C (0.1°F)
Temperature Accuracy: ±0.3°C (±0.5°F)
Calibration Points: 1 to 6 points with automatic buffer recognition (ABR)
ATC Temperature Calibration: Offset in 0.1°C increments; Offset range: ±5°C (±9°F)
Self-Test: Yes
Inputs: BNC, mini-phone ATC, 8 Pin DIN, ground
Power Requirements: 100 to 240VAC, 50/60Hz
Applications
Academic, research, QA/QC, drinking water, wastewater, food, beverage, industrial
Specification
Includes |
meter, TRIS Compatible pH/ATC Electrode (13-620-631), Conductivity/Temp Probe (13-620-100), Electrode Arm, RS232 and USB cables, 100/240V Power Supply |
Unit |
0 |
Qualifier |
cl_2645328 |
Productsapid |
13636AB200 |
Language |
engb |
Valueposition |
0 |
The information below is required for social login